X K 3 1 9 0
-
C 602
【
Setting
】
→
【
Input
】(
date setting
)
→
【
Input
】(
time setting
)
V. Printing
【
】
Print the current weight
(
in non-operating, non-setting status
)
.
Remark: Please confirm the type of printer before printing to avoid printing mistake.
VI.
Data Query and Removal
Method to Save Weighing Data
Set Parameter B in Parameter 9 of
【
SET 1
】
to 1, the
batching scale
will
automatically save the actual result of each w
eighing.
If it is set to 2, the
batching scale
will
automatically save every weighing time and actual weight, which cannot be accumulated
manually.
Searching Method
【
Setting
】
→
【
Input
】
→
【
Input
】
→
【
Input
】
(
search the total accumulated times
)
→
【
Input
】
(
search the total accumulated weight
)
→
【
Input
】
(
search the accumulated times of Channel 1
)
→
【
Input
】
(
search the accumulated weight of Channel 1
)
→
【
Input
】
(
search the accumulated times
of Channel 2
)
→
【
Input
】
(
search the accumulated weight of Channel 2
)
……. Press button
【
↓
】
or
【
↑
】
during the query. If the option at right side of the lower line shows ’1’, press button
【
Input
】
to print the accumulated times and accumulated weights. If the option shows ‘2’, press button
【
Input
】
to print all the weighing record.
The
serial
port
(
2
)
of PC can also be used to read the weighing record.
Accumulated Value Removal
Press button
【
Input
】
after the accumulated value is displayed and the instrument will
indicate , which means whether to remove the accumulate data. Press button
【
↑
】
→
【
Input
】
to clear
,
press
【
Input
】
directly not to clear. The communication port
(
2
)
of PC can also
be used to clear the weighing record.
VII. Operation /Stop
Press the button
【
Operation
】
or
【
Sop
】
on the keyboard, the instrument will enter running
[
AB
]
[
Auto P
]
[
0
]
[
dEL
]