X K 3 1 9 0
-
C 602
printer)
There is only English format for parameter print, the explanation is as follows
:
Content of print
Explanation
C602 Ver1.00
Instrument type and software version No.
Max=: 020.000kg
Max. capacity 20kg
e= : 01
Scale interval (effective bit) 1
Dp : 03
Decimals 3
0_AD: 00262121
AD code of calibrated zero point
0Point: 000.000kg
Current zero point (corresponding to calibrated zero
point)
R : 00067106
Standard rate
Line: 000.000%FS
Non-linear modification value
COMM:111110
Communication setting, corresponding to
【
SET 1
】
parameter 1
0_SET 141
Zero-setting
,
relative to
【
SET 1
】
parameter 2
Flt : 1222
Filtration setting, corresponding to
【
SET 1
】
parameter 3
Addr: 01
Communication address
,
corresponding to
【
SET 1
】
parameter 4
Buad: 44
Baud rate
,
corresponding to
【
SET 1
】
parameter 5
Mode: 22
Communication mode, corresponding to
【
SET 1
】
parameter 6
Prnt: 1
Printer type, corresponding to
【
SET 1
】
parameter 7
PL : 00
Print language, corresponding to
【
SET 1
】
parameter
8
AutoP 12
Automatic print, corresponding to
【
SET 1
】
parameter 9
Aout_W 020.000kg Full measurement range weight of analog output,
corresponding to
【
SET 1
】
parameter 10
Aout_0 00000
Zero DA code of analog output, corresponding to
【
SET 1
】
parameter 11
Aout_F 65070
Zero DA code of analog output, corresponding to
【
SET 1
】
parameter 12
Type: 212
Equipment type, corresponding to
【
SET 1
】
parameter 13
Disp: 04
Display content, corresponding to
【
SET 1
】
parameter 17
Light: 5
Display brightness, corresponding to
【
SET 1
】
parameter 16
F.3.1 Print of Working Parameters of Quantitative Scale