22
23
MAINTENANCE AND STORAGE
DANGER! Risk of injury!
Switch off the product and disconnect the mains plug before all cleaning and maintenance
work. Wait untill all moving parts are completely stopped.
Cleaning the device
• Brush off coarse dirt.
• Wipe down the device with a slightly damp cloth.
• Clean the collection bag regularly
Removing the collection bag
– Press the unlocking button and remove the collection bag.
Storage, transport
Storage
DANGER! Risk of injury! Make sure that unauthorized persons do not have access to the
device!
• Store the device in a dry place.
• Empty the collection bag before storing.
Transport
• Secure the device against slipping.
• If possible, use the original packaging for dispatching.
TROUBLESHOOTING
Fault/malfunction
Cause
Remedial measure
Motor not running
Battery pack discharged?
Fully charge the battery pack
Battery pack is not
connected correctly
Install the battery pack once again
Blower/Vacuum not power-
ful enough
Collection bag full?
Empty Collection bag
Suction speed too low?
Adjust the speed setting
CE DECLARATION
To the provisions of Council Directives
We
SUMEC UK
Unit A&B Escrick Business Park Escrick, York YO19 6FD/ United Kingdom
Declare that the product:
Description: 40V Cordless Blower/Vacuum
Model No. LB C20 / GY1782
Function: vacuuming and blowing leaves
Complies with the essential health and safety requirements of the
following directives:
Machinery Directive 2006/42/EC
Electromagnetic Compatibility Directive 2014/30/EU
EC Directive 2011/65/EU and its amendment Directive (EU) 2015/863 (RoHS)
Noise Emission in the Environment by Equipment for Use Outdoors Directive
2000/14/EC amended by 2005/88/EC
Measured Sound Power Level: 95 dB (A)
Declared Guaranteed Sound Power Level: 98 dB (A)
Standards and technical specification referred to:
EN 60335-1: 2012+ A11: 2014
EN 50636-2-100: 2014
EN 62233: 2008
EN 55014-1: 2017
EN 55014-2: 2015
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 50581: 2012
Authorized Signatory
Date: 18.10.2019
Signature:________________________
Place: York
Name: Mariana Hall
General Manager
SUMEC UK Co.,Ltd.
Unit A&B Escrick Business Park
Escrick,York YO19 6FD/ United Kingdom