background image

GENERAL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
1) WORK AREA
a) Keep work area clean and well lit.

Cluttered and dark areas invite accidents.

b) Do not operate pumps in explosive atmospheres, such as in the presence of flammable liquids,

gases, or dust. 

Pumps create sparks which may ignite the dust or fumes.

c) Keep children and bystanders away while operating a pump.

Distractions can cause you to lose control.

2) ELECTRICAL SAFETY
a) Pump plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs

with earthed (grounded) pumps.

Unmodified plugs and matching outlets will reduce risk of electric shock.

b) Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and

refrigerators.

There is an increased risk of electric shock if your body is earthed or grounded.

c) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump. Keep cord away

from  heat, oil, sharp edges or moving parts.

Damaged or entangled cords increase the risk of electric shock.

d) When operating a pump outdoors, use an extension cord suitable for outdoor use.

Use of a cord

suitable for outdoor use reduces the risk of electric shock.

3) PERSONAL SAFETY
a) Stay alert, watch what you are doing and use common sense when operating a pump. Do not use a

pump while you are tired or under the influence of drugs, alcohol or medication.

A moment of

inattention while operating pumps may result in serious personal injury.

b) Avoid accidental starting. Ensure the switch is in the off position before plugging in.

Carrying pumps

with your finger on the switch or plugging in pumps that have the switch on invites accidents.

c) Remove any adjusting key or wrench before turning the pump on.

A wrench or a key left attached to a

rotating part of the pump may result in personal injury.

d) Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away

from moving parts.

Loose clothes, jewellery or long hair can be caught in moving parts.

4) PUMP USE AND CARE
a) Disconnect the plug from the power source before making any adjustments, changing accessories,

or storing pumps.

Such preventive safety measures reduce the risk of starting the pump accidentally.

b) Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and any

other condition that may affect the pumps operation. If damaged, have the pump repaired before
use.

Many accidents are caused by poorly maintained pumps.

c) Use the pump, accessories and tool bits etc., in accordance with these instructions and in the manner

intended for the particular type of pump, taking into account the working conditions and the work to
be performed.

Use of the pump for operations different from intended could result in a hazardous situation.

5) SERVICE
a) Have your pump serviced by a qualified repair person using only identical replacement parts. 

This

will ensure that the safety of the pump is maintained.

b) If the supply cord is damaged,

it must be replaced by the manufacturer, its service agent or similarly

qualified persons in order to avoid a hazard.

7

Summary of Contents for YW1100TP

Page 1: ...all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Instruction Manual 1100...

Page 2: ...ACK CONTENTS FITTINGS AND TOOLS REQUIRED FOR INSTALLATION ELECTRICAL SAFETY DESCRIPTION OF SYMBOLS GENERAL SAFETY INSTRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS SET UP INSTALLATION OPERATION MA...

Page 3: ...se with a confirmed cash register receipt SHOULD YOU HAVE ANY QUESTIONS PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY OR REPAIR PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE Australia 1800 069 486 New...

Page 4: ...rous water transfer applications These include draining flooded laundries bathrooms basements or garages emptying rainwater tanks pools and spas emptying garden ponds and transferring water for domest...

Page 5: ...0TP 1 x Instruction manual 6 8 7 5 4 2 3 1 PACKED CONTENTS 4 Note Recommended items below are not included and are readily available from your local Bunnings store Suitable hose tube piping 2 x 25 4mm...

Page 6: ...mp is recommended to be protected by a 30mA residual current device or earth leakage circuit breaker If the power outlet is external ensure that it is weather proof If the supply cord is damaged it mu...

Page 7: ...ions or no No load speed reciprocation per minute l Litres C Degrees celsius p hr Per hour kPa Pressure rating kilopascals bar Pressure rating F Insulation class PVC Polyvinyl chloride IPX8 Ingress pr...

Page 8: ...personal injury b Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying pumps with your finger on the switch or plugging in pumps that have the switch on invit...

Page 9: ...ate under pressure Do not disconnect water pump or pipework until internal pressure has been released Failure to do this could result in personal injury and damage to property Avoid inserting hands in...

Page 10: ...be fitted to the suction line Note Teflon tape not included is required on threads to ensure a water tight seal and prevent any leakage 2 Insert a 25 4mm 1 male threaded hose adaptor not included into...

Page 11: ...iption on priming the pump Fig 4 5 m m 0 5 1 m m 0 5 1 WATER TANK GATE VALVE IN LINE FILTER NON RETURN VALVE UNION COUPLING SUCTION LINE FIRM BASE DISCHARGE OUTLET CONNECTION WITH TANK BASE LEVEL WITH...

Page 12: ...required on threads to ensure a water tight seal and prevent any leakage 1 Screw a 25 4mm 1 male threaded hose adaptor not included into the discharge outlet 2 Securely attach the output hose or pipe...

Page 13: ...2 Depress the ON OFF switch 8 to the l position Fig 9 3 To turn the pump off depress the ON OFF switch 8 to the 0 position Storing the Pump Before storing the pump it is recommended to empty the pump...

Page 14: ...ump body Use a moist cloth to wipe down the pump body 5 Allow to dry thoroughly before storing in a dry location that is protected from bad weather conditions If the pump is not going to be used for a...

Page 15: ...ermine the cause and unblock the pump The motor runs but the pump is not pumping water The pump is sucking air Verify the joints are sealed tightly The pump is not primed Fill the pump with water or w...

Reviews: