background image

15

MAINTENANCE

Storing the Pump

Before storing the pump, it is recommended to empty the pump body of any water.
Turn the drain screw (14) anti-clockwise and remove from the pump body. This will
drain any excess water. Replace the drain screw (14) (Fig. 14).

Changing the Oil
Note: 

After the first 25 hours of use the engine oil must be replaced, and then every 50 hours after that.

The high pressure pump is shipped without oil. Before starting ensure an oil inspection is conducted.
Always use high quality oils, choosing their viscosity grade according to the operating temperatures.

Note: 

It is recommended that SAE-10W-30 (multi viscosity) oils are used at temperatures from 5 to 35ºC and

synthetic oils 5W-30 (multi viscosity) is used for temperatures -5 to 5ºC.
1.  Place the high pressure pump on a level surface. 
2. Clean around the oil fill plug (15).
3.  Remove the oil fill plug (15) from both the left and right side of the engine 

(Fig. 15) and clean the dip stick and re-insert without screwing down.

4.  Remove the dipstick and ensure the oil lays between the 

min

and 

max

marks

(Fig. 16).

5. Fill the engine with SAE 10W-30 oil up to the max level of the oil gauge.

Note: 

Ensure the engine is not over filled with oil.

6. Fully retighten both the left and right oil fill plug (15).

Replacing the Air Filter

1.  Remove the cover by unscrewing and removing the plastic nut and cover (Fig. 17).
2.  Remove and inspect the filter. It must be intact and clean, if not either clean or

replace the filter.

3.  Replace the filter, filter cover and plastic nut. 

Fig. 14

Fig. 15

Fig. 16

Fig. 17

min max

Oil drain

plug

Summary of Contents for YW65PFF

Page 1: ...all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Instruction Manual 6 5H...

Page 2: ...PECIFICATIONS KNOW YOUR PRODUCT PACK CONTENTS DESCRIPTION OF SYMBOLS GENERAL SAFETY INSTRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS SET UP INSTALLATION OPERATION MAINTENANCE SPARE PARTS TROUBLES...

Page 3: ...ODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE TO ENSURE A SPEEDY RESPONSE PLE...

Page 4: ...ing rainwater tanks pools and spas emptying garden ponds and transferring water for domestic agricultural irrigation Motor Power 6 5HP Motor Type 4 Stroke air cooled Fuel Type Unleaded petrol Fuel Tan...

Page 5: ...Fuel Cap 2 Fuel Tank 3 Throttle Lever 4 Motor Housing 5 Recoil Starter 6 Fuel On Off Lever 7 Choke Lever 8 Air Filter 9 Exhaust 4 3 1 5 9 4 6 7 8 WARNING THIS PRODUCT IS NOT SUITABLE FOR USE WITH DRIN...

Page 6: ...KNOW YOUR PRODUCT cont 5 12 10 11 13 14 15 10 Priming Cap 11 Discharge Outlets 12 Pump Housing 13 Suction inlet 14 Drain Screw 15 Oil Fill Plug...

Page 7: ...ction Hose 17 25 4mm 1 Outlet Cap 18 25 4mm 1 Collar 19 25 4mm 1 Hose Adaptor 20 25 4mm 1 Hose Clamp 21 25 4mm 1 O ring 22 40mm 11 2 Inlet Outlet Cap 23 40mm 11 2 Collar 24 40mm 11 2 Hose Adaptor 25 4...

Page 8: ...11 2 Hose Clamps 3 x 40mm 11 2 O rings 1 x Filter 1 x Spark Plug Spanner 1 x Instruction Manual DESCRIPTION OF SYMBOLS Hp Horse power Hz Hertz Alternating current W Watts min Revolutions or no No load...

Page 9: ...ooting and balance at all times Proper footing and balance enables better control of the pump in unexpected situations d Use safety equipment Always wear eye protection Dust mask non skid safety shoes...

Page 10: ...ool before transporting or storing it indoors The muffler becomes very hot during operation and remains hot for a while after stopping the engine Exhaust may contain chemicals that may cause cancer or...

Page 11: ...to prevent the pipe from collapsing due to pressure from suction Caution All connections must be air tight failure to do so may result in an air leak which can prevent the pump from priming It is reco...

Page 12: ...used Fig 7 Note Multiple outlets can be used to pump water simultaneously but this will result in lower pressure and flow rate Note If the unused discharge outlets 11 are not blocked off this will re...

Page 13: ...for engine reliability of operation WARNING Do not over fill the fuel tank WARNING Do not smoke while re fueling 1 Use unleaded petrol with a minimum of Octane 91 2 Use clean fresh fuel purchase fuel...

Page 14: ...same 1 Use only the spark plug that is recommended for this high pressure petrol pump Champion RC12YC Note Using a spark plug other than that specified could lead to serious engine damage 2 Check the...

Page 15: ...Adjusting the Throttle The throttle is used to regulate the RPM of the engine which also controls the water flow out of the discharge outlet 1 To increase the speed of the engine and water flow move...

Page 16: ...thetic oils 5W 30 multi viscosity is used for temperatures 5 to 5 C 1 Place the high pressure pump on a level surface 2 Clean around the oil fill plug 15 3 Remove the oil fill plug 15 from both the le...

Page 17: ...ed from bad weather conditions If the pump is not going to be used for a long period of time it is advisable to rinse with water Ensure the pump is completely dry before storing 16 Fig 18 topupifrequi...

Page 18: ...low Fill with correct oil per operating instructions Choke adjusted incorrectly Move choke lever to CLOSED unless engine is warm Refer to engine operating instructions Unit starts but runs and perform...

Page 19: ...18...

Reviews: