How to use Digital Operation
12.1.8 Operation on the monitor mode
12-12
12.1.8 Operation on the monitor mode
On the monitor mode, you can observe the reference value input into the SERVOPACK, the
state of input/output signals, and the interior state of SERVOPACK.
The monitor mode can be changed even while the motor is running.
How to use the monitor mode
This is the procedure to view the monitor number Un000 data 1500 when the servo motor is
running at the speed of 1500 min
-1
.
1. On the monitor mode, select the axis you want to operate.
2. Press the [DSPL/ENTER] key to select the monitor mode.
3. Press the [UP] or [DOWN] key to view the monitor number you want.
4. Press the [DATA/ENTER] key to display the data of the monitor number you just
selected Step 3.
5. Press again the [DATA/ENTER] key to return to the monitor display.
This completes the view of the monitor number Un000 data 1500.
Data
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...