12.2 Application
12-23
12.2.5 Origin searching mode
The origin searching mode function enables to position and stop (cramp) at the origin pulse
position of encoder. This function can be used when the alignment of motor axis and
machine is required. Initiate the origin search without coupling.
The motor speed for the origin search is 60 min
-1
.
To search the origin, use the following procedure.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key to select the auxiliary mode.
3. Select the user constant Fn003. Press the [LEFT] or [RIGHT] key to select the setting
digit. Press [UP] or [DOWN] key until the value you want is displayed.
4. Press the [DATA/ENTER] key and the screen displays as below.
5. Press the [SVON] key. The indication will display as below to show that the origin
search mode is ready.
6. Keep on pressing the [UP] or [DOWN] key to execute the origin search.
If the user constant is Pn000.0 = 0 (standard setting), pressing the [UP] key enables the
motor to rotate forward, while pressing the [DOWN] key to rotate reverse. If the user
constant is Pn000.0 = 1, press the [DOWN] key to enable the motor to rotate forward
and press the [UP] key to rotate reverse.
Machine origin
The point where the motor
axis and the machine side
needs alignment.
Search is completed.
Keeps on flashing.
Increment: forward
Decrement: reverse
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...