How to use Digital Operation
12.2.6 Initializing the user constant setting value
12-24
7. Press the [DATA/ENTER] key to return to the auxiliary function execution mode dis-
play.
This completes the origin searching.
12.2.6 Initializing the user constant setting value
This function allows you to recover the standard setting (initial setting) even after changing
the user constants many times.
You must turn off the servo drive when activating this user constant initialization function .
To initialize the user constant, use the following procedure.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key and select the auxiliary function execution mode.
3. Select the user constant Fn005. Press the [LEFT] or [RIGHT] key to select the setting
digit. Press the [UP] or [DOWN] key until the value you want to set is displayed.
4. Press the [DATA/ENTER] key and the indication will display as below.
5. Press the [DSPL/SET] key. The new display like following initiates the user constant.
6. Press the [DATA/ENTER] key to return to the auxiliary function execution mode dis-
play.
This completes the initialization of user constant.
IMPORTANT
Flashes one
second.
Keep on flashing
while the initiation is
executed.
Stops
flashing.
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...