Installing the control panels
2.3.3 Orientation of and installation space for the SERVOPACK
2-16
2.3.3 Orientation of and installation space for the SERVOPACK
The SERVOPACK must be installed vertically and sufficient space must be provided around
them for better cooling efficiency, as shown below.
Fig. 2.6 SERVOPACK’s orientation and space
• All SERVOPACKs are designed so as to have their heat sink exposed to the outside.
• For the outside dimensions of and installation space for the SERVOPACKs, see the rele-
vant outline drawings given in the General Documentation - Hardware.
• The allowable temperature range of the air draft against the SERVOPACK is 0-45
℃
at
the heat sink (outside) and 0-55
℃
inside.
• Apply sealing agent to the mounting screw areas of the SERVOPACK to prevent oil
from entering inside.
• The SERVOPACK has a built-in fan as shown in Fig. 2.6.
• To prevent the SERVOPACK from overheating, arrange other units and devices such
that the required space is provided over and under the SERVOPACK.
• If an air stirring fan is installed in a panel, the fan must be oriented such that the air does
not directly hit the SERVOPACK (to prevent the SERVOPACK from collecting more
dust).
A space must be provided to the right and left of each SERVOPACK as follows:
SERVOPACK width
Space width
74 mm
0.5 mm (right and left)
148 or 248 mm
1.0 mm (right and left)
Air flow
Air flow
Heat
sink
120 mm
or more
5 mm or more
70 mm
max.
Upper and lower space
Left and right space
Converter Inverter
Servo unit
120 mm or more
Air duct within an
outermost enclosure
Sealing at screw
FAN
Air flow
Summary of Contents for CNC Series
Page 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Page 26: ...Part 1 Hardware...
Page 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Page 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Page 62: ...Installing the motors 3 4...
Page 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Page 96: ...Part 2 Software...
Page 102: ...Software configuration 6 6...
Page 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Page 121: ...7 2 Network settings 7 19...
Page 122: ...Part 3 PLC...
Page 154: ...Part 4 Setting up and maintenance...
Page 160: ...Overview of System 10 1 2 Basic operation 10 6...
Page 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Page 327: ...Error and Troubleshooting 15 4...
Page 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Page 329: ...Error and Troubleshooting 15 6...
Page 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...