DS - Record set for access via CPU, PROFIBUS and PROFINET
IX - Index for access via CANopen
SX - Subindex (3100h + EtherCAT-Slot) for access via EtherCAT
More can be found in the according manual of your bus coupler.
Name
Bytes
Function
Default
DS
IX
SX
DIAG_EN
1
Diagnostic interrupt*
00h
00h
3100h
01h
CH0A
1
Input frequency track A
02h
01h
3101h
02h
CH1B
1
Input frequency track B
02h
01h
3102h
03h
CH2L
1
Input frequency Latch
02h
01h
3103h
04h
CH3G
1
Input frequency Gate
02h
01h
3104h
05h
CH4R
1
Input frequency Reset
02h
01h
3105h
06h
CH5
1
reserved
00h
01h
3106h
07h
INT_I
1
Interrupt behavior*
80h
80h
3107h
08h
FCT_I
1
Counter function*
40h
80h
3108h
09h
MODE2_I
1
Counter mode 2*
00h
80h
3109h
0Ah
MODE3_I
1
Counter mode 3*
00h
80h
310Ah
0Bh
END_I
4
End value
00h
81h
310Bh...
310Eh
0Ch
LOAD_I
4
Load value
00h
81h
310Fh...
3112h
0Dh
HYST_I
1
Hysteresis
00h
81h
3113h
0Eh
PULSE_I
1
Pulse
00h
81h
3114h
0Fh
*) This parameter may only be transferred at STOP state.
Byte
Bit 7...0
0
Diagnostic interrupt
n
00h = disable
n
40h = enable
n
Here you activate res. de-activate the diagnostic function.
Byte
Function
Possible values
0
Input frequency track A
n
02h: 100kHz
n
03h: 60kHz
n
04h: 30kHz
n
06h: 10kHz
n
07h: 5kHz
n
08h: 2kHz
n
09h: 1kHz
1
Input frequency track B
2
Input frequency Latch
3
Input frequency Gate
Parameters
DIAG_EN Diagnostic
interrupt
CHxx Input frequency
VIPA System SLIO FM 050
Deployment
Parameter data
HB300 | FM | 050-1BA00 | GB | 15-11