With reaching the comparison condition the
hysteresis
gets active. At
active
hysteresis
the comparison result remains unchanged until the
counter value
leaves the set
hysteresis
range. After leaving the
hyste-
resis
range a new
hysteresis
is only activated with again reaching the
comparison conditions.
1
Counter value
=
comparison value
®
output is set and
hysteresis
activated
2 Leave
hysteresis
range
®
output is reset and
counter value
<
comparison value
3
Counter value
=
comparison value
®
output is set and
hysteresis
activated
4 Output is reset for leaving
hysteresis
range and
counter value
>
comparison value
5
Counter value
=
comparison value
®
output is set and
hysteresis
activated
6
Counter value
=
comparison value
and
hysteresis
active
®
output
remains set
7 Leave
hysteresis
range and
counter value
>
comparison value
®
output is reset
With reaching the comparison condition the
hysteresis
gets active. At
active
hysteresis
the comparison result remains unchanged until the
counter value
leaves the set
hysteresis range
. After leaving the
hyste-
resis
range a new
hysteresis
is only activated with again reaching the
comparison conditions.
Effect at pulse at com-
parison value with
pulse duration Zero
VIPA System SLIO FM 050
Deployment
Counter additional functions
HB300 | FM | 050-1BA00 | GB | 15-11
58