EMC
Standard
Comment
Emitted interference
EN 61000-6-4
Class A (Industrial area)
Noise immunity
zone B
EN 61000-6-2
Industrial area
EN 61000-4-2
ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2)
EN 61000-4-3
HF field immunity (casing)
80MHz … 1000MHz, 10V/m, 80% AM (1kHz)
1.4GHz ... 6.0GHz, 3V/m, 80% AM (1kHz)
EN 61000-4-6
HF conducted
150kHz … 80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4
Burst, degree of severity 3
EN 61000-4-5
Surge, degree of severity 3
1
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is
necessary.
2.6 Use in difficult operating conditions
Without additional protective measures, the products must not be used in
locations with difficult operating conditions; e.g. due to:
–
dust generation
–
chemically active substances (corrosive vapors or gases)
–
strong electric or magnetic fields
2.7 Technical data
2.7.1 67K-RTP0-KB
Order no.
67K-RTP0-KB
Type
Panel PC PPC010 IE
Display
Display size (diagonal)
10,1 "
Display size (width)
217 mm
Display size (height)
136 mm
Resolution
800 x 1280 / 1280 x 800
Aspect ratio
16:10
Type of display
TFT color (262K colors)
MTBF Backlights (25°C)
50000 h
System properties
HMI
Hardware description
Technical data > 67K-RTP0-KB
HB160 | PPC | 67K-RTP0 | en | 22-22
18
Summary of Contents for 67K-RTP0
Page 1: ...PPC 67K RTP0 Manual HB160 PPC 67K RTP0 en 22 22 HMI Panel PC PPC010 IE...
Page 13: ...HMI Hardware description Structure Interfaces HB160 PPC 67K RTP0 en 22 22 13...
Page 71: ...Appendix HMI Appendix HB160 PPC 67K RTP0 en 22 22 71...
Page 72: ...Content A History of changes 73 HMI Appendix HB160 PPC 67K RTP0 en 22 22 72...