For the cabling of the power supply DC 12-30V a green plug is used. The connector is a
plug with screw contacts. The plug has the following assignment:
+
DC 24V
-
DC 0V
PE Protective earth
3.2 Installation of the CFast card
The CFast card slot is located on the rear top side of the Panel PC. It is closed with a
cover plate.
1.
Remove the cover plate of the slot by removing the screws and pulling the plate.
2.
With the label facing up, insert the CFast card until it is completely seated in the slot
and reinstall the cover plate.
ð
After installation the CFast card is automatically recognized.
1.
Remove the screws.
2.
Pull the holding plate from the card slot.
3.
Push the CFast card to remove the card.
4.
Reinstall the cover plate.
CAUTION!
Prior to removing the CFast card, make sure the unit's power is off and
disconnected from the power supply.
Connect power supply
Installation
Demounting