The SI-P1 card can be mounted on these inverters.
VS-616G5:Standard series (Operates on inverter software No.S1042 or later edition)
Varispeed F7:Standard series
Varispeed G7:Standard series
Description
Code No.
Function
SI-P1
PROFIBUS-DP
Communication
Interface Card SI-P1
73600-C033X PROFIBUS data
Extended data 1 (Data length:32 bytes)
High-speed I/O data area (input:16bytes, output
16bytes)
MEMOBUS message (input:16bytes, output 16bytes)
Extended data 2 (Data length:12bytes)
High-speed I/O data area (input:4bytes, output 4bytes)
MEMOBUS message (input:8bytes, output 8bytes)
Basic data (Data length:6 bytes)
High-speed I/O data area (input:6bytes, output 6bytes)
Communication speed:9.6kbps to 12Mbps
:
Before Use
(1)
Read this instruction manual and the instruction manual of the inverter on which the PROFIBUS-
DP Communications Interface Card SI-P1 is to be mounted before using the PROFIBUS-DP
Communications Interface Card SI-P1
(2)
Connect the PROFIBUS-DP communications interface card SI-P1 to the connectors or external
terminals where the inverter power supply is turned OFF and the inverter CHARGE indicator
lamp is extinguished.
(3)
Specify the name and code number when placing an order of the PROFIBUS-DP communications
interface card SI-P1.
Fig. 1 PROFIBUS-DP Communications Interface Card SI-P1
NOTE
Connector with Inverter
Control Board (JP1)
PROFIBUS-DP
Bus Connection
Terminal (JP3)
Termination
Resistor
Selector
Switich
Address Switch 2
(
×
10)
Address Switch 1
(
×
1)
Ground Lead
Wire
Status Display LED
Spacer
Mounting Hole
Model and
Code No.
SI-P1
73600-C0331