User Parameter Tables
5-
31
Reference Frequency Hold: d4
User parameters for the reference frequency hold function are shown in the following table.
Torque Control: d5
User parameters for the torque control are shown in the following table.
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
d4-01
Frequency
Reference
Hold
Function
Selection
This parameter is used to
retain the held frequency
reference in U1-01 (d1-01)
when power is removed. This
function is available when the
multi-function inputs “accel/
decel ramp hold” or
“up/down” commands are
selected (H1-XX = A or 10
and 11).
0: Disabled
1: Enabled
0 or 1
0
No
A
A
A
A
A
298H
MOP Ref
Memory
d4-02
Trim Control
Lvl
Sets the amount of frequency
reference to be added or
subtracted as a percentage of
maximum output frequency
(E1-04) when multi-function
inputs “trim control increase”
and “trim control decrease”
are selected (H1-XX = 1C
and 1D).
0
to
100
10%
No
A
A
A
A
A
299H
Trim Control
Lvl
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
d5-01
Torque
Control
Selection
Selects speed or torque control.
The torque reference is set via
analog input A2 or A3 when it
is set for "torque reference"
(H3-05 or H3-09 = 13). Torque
reference is set as a percentage
of motor rated torque. To use
this function for switching
between speed and torque
control, set to 0 and set a multi-
function input to "speed/torque
control change" (H1-xx = 71).
0: Speed Control (controlled
by C5-01 to C5-07)
1: Torque Control
0 or 1
0
No
No
No
No
A
A
29AH
Torq Control
Sel
d5-02
Torque
Reference
Delay Time
Sets the torque reference
delay time in milliseconds.
This function can be used to
correct for noise in the torque
control signal or the
responsiveness with the host
controller. When oscillation
occurs during torque control,
increase the set value.
0
to
1000
0ms
*
No
No
No
No
A
A
29BH
Torq Ref
Filter
Summary of Contents for CIMR-G7U
Page 2: ......
Page 7: ...v...
Page 32: ...1 18...
Page 90: ...3 16...
Page 112: ...4 22...
Page 382: ...6 164...
Page 410: ...7 28...
Page 454: ......
Page 455: ......