User Parameter Tables
5-
91
U1-44
ASR
Output
without
Filter
Output from the speed control
loop (ASR) before the ASR
primary delay filter (C5-06).
100% is displayed for rated
secondary current of the
motor.
10V: Motor Rated Secondary
Current
(0V to ±10V)
0.0
1%
No
No
No
A
A
6BH
ASR
Output w
Fil
U1-45
Feed
Forward
Control
Output
Output from feed forward
control. 100% is displayed for
rated secondary current of the
motor.
10V: Motor Rated Secondary
Current
(0V to ±10V)
0.0
1%
No
No
No
A
A
6CH
FF Cout
Output
U1-50
CF Fault
Error Code
Displays the code for a CF
fault:
00: No deceleration for 3sec
after reaching the stop
frequency.
01: Flux estimation fault.
02: Start status error.
04: Observer gain adjustment
error.
08: Regeneration error at low
speeds.
10: Zero Speed error.
20: Rotational Direction Limit
error.
80: Vector control status error
Setting Range
(0 thru FFFFFH)
-
No
No
No
No
A
71H
CF Error
Code
Parameter
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MODBUS
Register
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
Summary of Contents for CIMR-G7U
Page 2: ......
Page 7: ...v...
Page 32: ...1 18...
Page 90: ...3 16...
Page 112: ...4 22...
Page 382: ...6 164...
Page 410: ...7 28...
Page 454: ......
Page 455: ......