Individual Functions
6-
137
Multi-function Contact Input Functions (H1-01 to H1-10)
Multi-function Contact Output Functions (H2-01 to H2-03)
To output the zero-servo status externally, assign the Zero Servo End signal (setting 33) to one of the multi-
function outputs (H2-01 to H2-03).
Monitor Function
Setting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
72
Zero-servo command (ON: Zero-servo)
No
No
No
Yes
No
Setting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
33
Zero-servo end
ON: Current position is within zero-servo start position ± the zero-servo end width.
No
No
No
Yes
No
Parameter
Number
Name
Description
Output Signal Level During
Multi-Function
Analog Output
Min.
Unit
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
U1-35
Zero-servo
movement
pulses
Shows the number of PG pulses
times 4 for the movement range
when stopped at zero.
(Cannot be output.)
1
No
No
No
A
No
Zero Servo
Pulse
Summary of Contents for CIMR-G7U
Page 2: ......
Page 7: ...v...
Page 32: ...1 18...
Page 90: ...3 16...
Page 112: ...4 22...
Page 382: ...6 164...
Page 410: ...7 28...
Page 454: ......
Page 455: ......