A.1 Power Ratings
Table A.1 Power Ratings (Three-Phase 200 V Class)
Table A.2 Power Ratings (Three-Phase 400 V Class)
Item
<1> Rated output capacity is calculated with a rated input voltage of 200 V.
Specification
Model
2A03P5 2A0005 2A0007 2A0010 2A0014 2A0017 2A0020 2A0028 2A0035 2A0053 2A0073 2A0105
Maximum Applicable Motor
Capacity [kW]
3.7
5.5
7.5
11
15
18.5
22
30
37
55
75
110
Rating
Rated Output
Capacity [kW]
3.5
5
7
10
14
17
20
28
35
53
73
105
Rating
Rated Output Current
(DC) [A]
14
20
27
41
55
68
81
112
138
207
282
413
Rated Input Current
(AC) [A]
10
15
20
30
41
50
60
83
102
153
209
306
Item
<1> Rated output capacity is calculated with a rated input voltage of 400 V.
Specification
Model
4A03P5
4A0005
4A0007
4A0010
4A0014
4A0017
4A0020
4A0028
Maximum Applicable Motor
Capacity [kW]
3.7
5.5
7.5
11
15
18.5
22
30
Rating
Rated Output Capacity
3.5
5
7
10
14
17
20
28
Rating
Rated Output Current
(DC) [A]
7
11
15
22
30
36
43
58
Rated Input Current
(AC) [A]
5
8
11
16
22
27
32
43
Item
<1> Rated output capacity is calculated with a rated input voltage of 400 V.
Specification
Model
4A0035
4A0043
4A0053
4A0073
4A0105
4A0150
4A0210
4A0300
Maximum Applicable Motor
Capacity [kW]
37
45
55
75
110
160
220
315
Rating
Rated Output Capacity
35
43
53
73
105
150
210
300
Rating
Rated Output Current
(DC) [A]
73
89
109
149
217
320
440
629
Rated Input Current
(AC) [A]
54
66
81
110
161
237
326
466
TOEP_C710656_10B_1_0.book 138 ページ 2015年1月8日 木曜日 午後8時55分