7 Periodic Inspection and Maintenance
YASKAWA ELECTRIC
SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
383
1.
Connect the drive and the fan connector.
A - Cooling Fan
B - Fan unit base
C - Circulation Fans
Figure 7.52 Connect Connector
2.
Align the pins on the fan unit base with the notches on the fan, and use the screws to safety.
Tighten the M4 screws to a tightening torque of 0.98 N
∙
m to 1.33 N
∙
m (8.67 lb.
∙
in. to 11.77 lb.
∙
in.).
A - Cooling Fan
B - Fan unit base
C - Circulation Fans
Figure 7.53 Install the Cooling Fan
Note:
When you install the cooling fan, make sure that you do not pinch cables between the cooling fan and the fan unit base.
3.
Put the cables in their initial locations.
Note:
Safety the relay cable to the hook.
A
B
C