YASKAWA ELECTRIC
SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
459
Setting
Function
Description
Ref.
C
Analog Terminal
Enable Selection
Sets the command that enables or disables the terminals selected in
H3-14 [Analog Input
Terminal Enable Sel]
.
ON : Input to the terminal selected with
H3-14
is enabled
OFF : Input to the terminal selected with
H3-14
is disabled
D
Ignore Speed Fdbk
(V/f w/o Enc)
Sets the command to disable speed feedback control and run the drive in V/f control or
use speed feedback from the encoder.
ON : Speed feedback control disable (V/f Control)
OFF : Speed feedback control enable (Closed Loop V/f Control)
E
ASR Integral Reset
Sets the command to reset the integral value and use PI control or P control for the speed
control loop.
ON : P control
OFF : PI control
F
Not Used
Setting for terminals that are not being used or terminals being used in through mode.
10
Up Command
It is paired with setting value 11 (Down Command). When using the Up command and
Down command, the user can increase and decrease the frequency reference of the drive
using two push buttons.
ON : Increases the frequency reference.
OFF : Holds the current frequency reference.
11
Down Command
It is paired with setting value 10 (Up Command). When using the Up command and
Down command, the user can increase and decrease the frequency reference of the drive
using two push buttons.
ON : Decreases the frequency reference.
OFF : Holds the current frequency reference.
12
Forward Jog
Sets the command to operate the motor in the forward direction at the Jog Frequency set
in
d1-17 [Jog Reference]
.
13
Reverse Jog
Sets the command to operate the motor in the reverse direction at the Jog Frequency set
in
d1-17 [Jog Reference]
.
14
Fault Reset
Sets the command to reset the current fault when the Run command is inactive.
15
Fast Stop (N.O.)
Sets the command to ramp to stop in the deceleration time set in
C1-09 [Fast Stop Time]
when the input terminal is ON while the drive is operating.
16
Motor 2 Selection
Switches between motors 1 and 2. Switch between motors when they are stopped.
ON : Selects motor 2
OFF : Selects motor 1
17
Fast Stop (N.C.)
Sets the command to ramp to stop in the deceleration time set in
C1-09 [Fast Stop Time]
when the input terminal is ON while the drive is operating.
1A
Accel/Decel Time
Selection 2
Set this function and
H1-xx = 7[Accel/decel Time Selection 1]
together. Sets the drive to
use
Acceleration/Deceleration Time 3 [C1-05, C1-06]
or
Acceleration/Deceleration Time
4 [C1-07, C1-08]
.
1B
Programming
Lockout
Sets the command to prevent parameter changes when the terminal is OFF.
ON : Program Lockout
OFF : Parameter Write Prohibit
1E
Reference Sample
Hold
The analog frequency reference input via terminal A1, A2 or A3 will be sampled and
operation will continue at that frequency.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV