E3-11: Motor 2 Mid Point B Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-11
(0345)
Expert
Motor 2 Mid Point B
Frequency
Sets a middle output frequency for the motor 2 V/f pattern. Set this
parameter to adjust the V/f pattern for the constant output range. Usually it
is not necessary to change this setting.
0.0 Hz
(0.0 - E3-04)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
E3-12: Motor 2 Mid Point B Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-12
(0346)
Expert
Motor 2 Mid Point B
Voltage
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter
to adjust the V/f pattern for the constant output range. Usually it is not
necessary to change this setting.
0.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
E3-13: Motor 2 Base Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-13
(0347)
Expert
Motor 2 Base Voltage
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust
the V/f pattern for the constant output range. Usually it is not necessary to
change this setting.
0.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Note:
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
E3-14: M2 Middle Out Freq Volt Select
No.
(Hex.)
Name
Description
Default
(Range)
E3-14
(114E)
M2 Middle Out Freq
Volt Select
Sets the mid point A voltage for motor 2 reverse run used when
b1-23 = 1
[Selection REV Parameters = Enabled]
.
Determined by E3-01
and E1-03
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
E3-15: M2 Minimum Out Freq Volt Select
No.
(Hex.)
Name
Description
Default
(Range)
E3-15
(114F)
M2 Minimum Out
Freq Volt Select
Sets the minimum output voltage for motor 2 reverse run used when
b1-23
= 1 [Selection REV Parameters = Enabled]
.
Determined by E3-01
and E1-03
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
E3-20: UL Motor2 Sel
No.
(Hex.)
Name
Description
Default
(Range)
E3-20
(0BF4)
UL Motor2 Sel
Sets the motor characteristics.
2
(0 - 2)