2 Mechanical & Electrical Installation
84
YASKAWA ELECTRIC
SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
1.
Remove the screws on the terminal block cover and pull the terminal block cover away from the drive. Pull
the wiring cover away from the drive to remove the wiring cover after removing the terminal block cover.
A - Terminal block cover
B - Wiring cover
Figure 2.96 Remove the Wiring Cover
2.
Remove the terminal block nut.
A - Nut
Figure 2.97 Remove the Terminal Block Nut
3.
Wire the closed-loop crimp terminal to the main circuit terminal block.
Figure 2.98 Install the Electrical Wire
4.
Tighten the nut to the specified torque.
Figure 2.99 Tighten the Terminal Block Nut
5.
Check the signal from the wired terminal and use a diagonal-cutting pliers to remove areas of the wiring
cover cutaway section.
Cut the areas shown in Figure 2.100.