background image

Yaskawa AC Drive

Fan Replacement Procedure

In the event that the end user of this product is to be the military and said product is to be
employed in any weapons systems or the manufacture thereof, the export will fall under the
relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations.
Therefore, be sure to follow all procedures and submit all relevant documentation according to
any and all rules, regulations and laws that may apply.

Specifications are subject to change without notice for ongoing product modifications and
improvements.

© 2020 YASKAWA Electric Corporation

MANUAL NO. TOEP C730600 0GA <0>-0

Published in Japan June 2020
20-2-15

*TOEPC7306000G*

DRIVE CENTER (INVERTER PLANT)

2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan
Phone: +81-930-25-2548 Fax: +81-930-25-3431

www.yaskawa.co.jp

YASKAWA ELECTRIC CORPORATION

New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-6891, Japan
Phone: +81-3-5402-4502 Fax: +81-3-5402-4580

www.yaskawa.co.jp

YASKAWA AMERICA, INC.

2121, Norman Drive South, Waukegan, IL 60085, U.S.A.
Phone: +1-800-YASKAWA (927-5292) or +1-847-887-7000 Fax: +1-847-887-7310

www.yaskawa.com

YASKAWA EL

É

TRICO DO BRASIL LTDA.

777, Avenida Piraporinha, Diadema, S

ã

o Paulo, 09950-000, Brasil

Phone: +55-11-3585-1100 Fax: +55-11-3585-1187

www.yaskawa.com.br

YASKAWA EUROPE GmbH

Hauptstra

β

e 185, 65760 Eschborn, Germany

Phone: +49-6196-569-300 Fax: +49-6196-569-398
E-mail:

info@yaskawa.eu.com

www.yaskawa.eu.com

YASKAWA ELECTRIC KOREA CORPORATION

35F, Three IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul, 07326, Korea
Phone: +82-2-784-7844 Fax: +82-2-784-8495

www.yaskawa.co.kr

YASKAWA ASIA PACIFIC PTE. LTD

30A, Kallang Place, #06-01, 339213, Singapore
Phone: +65-6282-3003 Fax: +65-6289-3003

www.yaskawa.com.sg

YASKAWA ELECTRIC (THAILAND) CO., LTD.

59, 1F-5F, Flourish Building, Soi Ratchadapisek 18, Ratchadapisek Road, Huaykwang, Bangkok, 10310, Thailand
Phone: +66-2-017-0099 Fax: +66-2-017-0799

www.yaskawa.co.th

YASKAWA ELECTRIC (CHINA) CO., LTD.

22F, Link Square 1, No.222, Hubin Road, Shanghai, 200021, China
Phone: +86-21-5385-2200 Fax: +86-21-5385-3299

www.yaskawa.com.cn

YASKAWA ELECTRIC (CHINA) CO., LTD. BEIJING OFFICE

Room 1011, Tower W3 Oriental Plaza, No. 1, East Chang An Avenue,
Dong Cheng District, Beijing, 100738, China
Phone: +86-10-8518-4086 Fax: +86-10-8518-4082

YASKAWA ELECTRIC TAIWAN CORPORATION

12F, No. 207, Section 3, Beishin Road, Shindian District, New Taipei City 23143, Taiwan
Phone: +886-2-8913-1333 Fax: +886-2-8913-1513 or +886-2-8913-1519

www.yaskawa.com.tw

YASKAWA INDIA PRIVATE LIMITED

#17/A, Electronics City, Hosur Road, Bengaluru, 560 100 (Karnataka), India
Phone: +91-80-4244-1900 Fax: +91-80-4244-1901

www.yaskawaindia.in

Summary of Contents for CIPR-GA50 AJ Series

Page 1: ...MANUAL NO TOEP C730600 0GA Yaskawa AC Drive Fan Replacement Procedure Applicable Drive Model CIPR GA50xxxxxxxxx To properly use the product read this manual...

Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEP C730600 0GA Fan Replacement Procedure...

Page 3: ...2 Explanation of Signal Words 4 3 Section Safety 4 4 Drive Models and Number of Fans 5 5 Replace Cooling Fans 5 Replace the Cooling Fan Procedure A 5 Remove a Fan 6 Install a Fan 6 Replace the Coolin...

Page 4: ...on the drive when it is energized it will cause serious injury or death from electrical shock DANGER Electrical Shock Hazard Disconnect all power to the drive and wait for the time specified on the wa...

Page 5: ...ocedure A DANGER Electrical Shock Hazard Do not examine connect or disconnect wiring on an energized drive Before servicing disconnect all power to the equipment and wait for the time specified on the...

Page 6: ...ooks on the left and right sides of it and pull up A Fan finger guard Figure 5 1 Remove the Fan Finger Guard 2 Pull the cooling fan straight up from the drive Disconnect the power supply connector and...

Page 7: ...ure 5 3 Connect the Power Supply Connector 2 Align the notches on the fan with the pins on the drive and install the cooling fans in the drive A Alignment pins on drive B Front of drive C Notch on fan...

Page 8: ...ble and connector in the recess of the drive A Front of drive Figure 5 5 Put the Cable and Connector in the Drive Recess Note The connector installation position is different for different models Figu...

Page 9: ...ernal capacitor stays charged after the drive is de energized The charge indicator LED extinguishes when the DC bus voltage decreases below 50 Vdc When all indicators are OFF measure for dangerous vol...

Page 10: ...emove the fan finger guard from the drive A Fan finger guard Figure 5 10 Remove the Fan Finger Guard 2 Pull the cooling fan straight up from the drive Disconnect the power supply connector and remove...

Page 11: ...ling fan Figure 5 12 Connecting the power supply connector 2 Install the cooling fans so that they align with the pins on the drive A Alignment pins on drive B Front of drive C Notches Figure 5 13 Ins...

Page 12: ...of drive Figure 5 14 Putting the cable and connector in the recess 4 Insert the tabs of the fan cover into the holes in the drive and press in the fan cover until the hook clicks into place Figure 5...

Page 13: ...YASKAWA TOEP C730600 0GA Fan Replacement Procedure 13 Revision History Date of Publication Revision Number Section Revised Content June 2020 First Edition...

Page 14: ...S o Paulo 09950 000 Brasil Phone 55 11 3585 1100 Fax 55 11 3585 1187 www yaskawa com br YASKAWA EUROPE GmbH Hauptstra e 185 65760 Eschborn Germany Phone 49 6196 569 300 Fax 49 6196 569 398 E mail info...