4.3 Wiring the Power Supply to the SERVOPACK
4.3.1 Terminal Symbols and Terminal Names
4-13
4
W
iring and Connecting
•
Single-Phase, 200-VAC Power Supply Input
You can use a single-phase, 200-V power supply input with the following models.
•
SGD7S-R70A, -R90A, -1R6A, -2R8A, -5R5A
If you use a single-phase, 200-VAC power supply input for the SERVOPACK’s main circuit
power supply, set parameter Pn00B to n.
1
(Use a three-phase power supply input as a
single-phase power supply input). Refer to the following section for details.
5.2.2 Single-phase AC Power Supply Input/Three-phase AC Power Supply Input Setting
•
DC Power Supply Input
If you use a DC power supply input to the SERVOPACK, make sure to set parameter Pn00E
to n.
1 (DC power supply input supported) before inputting the power supply. Refer to
the following section for details.
5.2.1 AC Power Supply Input/DC Power Supply Input Setting
Terminal
Symbols
Terminal Name
Specifications and Reference
L1, L2
Main circuit power supply
input terminals for AC
power supply input
Single-phase, 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60
Hz
L1C, L2C
Control power supply termi-
nals
Single-phase, 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60
Hz
B1/ , B2, B3
Regenerative Resistor termi-
nals
4.3.5 Wiring Regenerative Resistors
For SGD7S-R70A, -R90A, -1R6A, and -2R8A
If the regenerative capacity is insufficient, connect an Exter-
nal Regenerative Resistor between B1/
and B2.
The External Regenerative Resistor is not included. Obtain it
separately.
For SGD7S-5R5A and -120AE0A008
If the internal regenerative resistor is insufficient, remove the
lead or short bar between B2 and B3 and connect an Exter-
nal Regenerative Resistor between B1/
and B2.
The External Regenerative Resistor is not included. Obtain it
separately.
1, 2
DC Reactor terminals for
power supply harmonic
suppression
4.3.6 Wiring Reactors for Harmonic Suppression
These terminals are used to connect a DC Reactor for power
supply harmonic suppression or power factor improvement.
L3,
−
None. (Do not connect anything to these terminals.)
You do not need to change the setting of Pn00B to n.
1
(Use a three-phase power sup-
ply input as a single-phase power supply input) for a SERVOPACK with a single-phase 200-
VAC power supply input (model number: SGD7S-120AE0A008).
Terminal
Symbols
Terminal Name
Specifications and Reference
L1C, L2C
Control power supply termi-
nals
L1C: 270 VDC to 324 VDC, -15% to +10%, L2C: 0 VDC
Or
L2C: 270 VDC to 324 VDC, -15% to +10%, L1C: 0 VDC
B1/
Main circuit power supply
input terminals for DC
power supply input
270 VDC to 324 VDC, -15% to +10%
2
0 VDC
L1, L2, L3,
B2, B3,
1,
−
None. (Do not connect anything to these terminals.)
Information