7 Digital Operator/Panel Operator
7.3.1 Setting Parameters
7-22
(c) Parameter Indications
In this manual, the parameter is explained with using the following format.
The following alarm shows the setting value of the parameter.
(2) Function Selection Parameters
(a) Types of Function Selection Parameters
Refer to
11.3.2 List of Parameters.
If the parameters with “After restart” in “Setting Validation” column in the table are changed, turn OFF the
main circuit and control power supply and ON again to validate new setting.
• Pn10B.1 requires the power to be reset as mentioned above.
Decimal display in five digits
Pn406
Emergency Stop Torque
Setting Range
0 to 800
1%
800
Immediately
Setting Unit
Factory Setting
Setting Validation
The number of the
parameter
The name of the
parameter
Position
Positoin
Speed
Torque
Torque
Applicable control mode for the parameter
Speed
: Speed control, internally set speed control
: Position control
: Torque control
This section shows the
range of the parameter
settings. The maximum
value can be set even if
the parameter is combined
with the other sepecified
motor.
This section shows the
minimum setting unit
(the setting value).
This section shows the
SERVOPACK's parameter
with factory setting.
This section shows if
the setting is validated
"immediately" or "after
restart" when changing
the parameter.
Category
Parameter
No.
Name
Factory
Setting
Setting
Validation
Function Selection
Parameter
Pn000
Function Selection Basic Switches
0000
After restart
Pn001
Function Selection Application Switches
0000
After restart
Pn002
Function Selection Application Switches
0000
After restart
Pn003
Function Selection Application Switches
0002
Immediately
Servo Gain Related
Parameter
Pn10B
Gain Application Switches
0000
After restart/
Immediately
Position Control Related
Parameter
Pn200
Position Control References Selection Switches
0000
After restart
Pn207
Position Control Function Switches
0000
After restart
Sequence Related
Parameter
(Input Signal Selection)
Pn50A
Input Signal Selections
2100
After restart
Pn50B
Input Signal Selections
6543
After restart
Pn50C
Input Signal Selections
8888
After restart
Pn50D
Input Signal Selections
8888
After restart
Sequence Related
Parameter
(Output Signal Selection)
Pn50E
Output Signal Selections
3211
After restart
Pn50F
Output Signal Selections
0000
After restart
Pn510
Output Signal Selections
0000
After restart
Pn512
Output Signal Reversal Setting
0000
After restart
IMPORTANT