11.3 List of Parameters
11-25
11
Appendix
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Pn50C
Input Signal Selections 3
−
−
8888
After restart
0
1
2
3
4
5
6
7
8
9
A
B
ON when CN1-40 input signal is ON (L-level).
ON when CN1-41 input signal is ON (L-level).
ON when CN1-42 input signal is ON (L-level).
ON when CN1-43 input signal is ON (L-level).
ON when CN1-44 input signal is ON (L-level).
ON when CN1-45 input signal is ON (L-level).
ON when CN1-46 input signal is ON (L-level).
Sets signal ON.
Sets signal OFF.
ON when CN1-40 input signal is OFF (H-level).
ON when CN1-41 input signal is OFF (H-level).
ON when CN1-42 input signal is OFF (H-level).
ON when CN1-43 input signal is OFF (H-level).
0 to F
Same as /SPD-D
0 to F
Same as /SPD-D
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
ON when CN1-44 input signal is OFF (H-level).
ON when CN1-45 input signal is OFF (H-level).
ON when CN1-46 input signal is OFF (H-level).
C
D
E
F
0 to F
Same as /SPD-D
/SPD-D Signal Mapping
/SPD-A Signal Mapping
/SPD-B Signal Mapping
/C-SEL Signal Mapping (Control mode change when ON (L-level))