5.4 Setting Stop Functions
5 -65
Output /
BK
Brake Interlock Output
Speed/Torque
Control,
Position Control
This output signal controls the brake when using a Servomotor with a brake and does not have
to be connected when using a Servomotor without a brake.
ON:
Closed or low level
Releases the brake.
OFF:
Open or high level
Applies the brake.
Related User Constants
Pn506
Time Delay from Brake Reference until Servo OFF
Pn507
Speed Level for Brake Reference Output during Motor Operation
Pn508
Timing for Brake Reference Output during Motor Operation
The output signal in the following user constant must be selected when the /BK signal is used.
Pn50F
Output Signal Selections 2
Setting
Range:
0000
Speed/Torque
Control,
Position Control
/BK
Brake interlock
output
Pn50F.2
1
2
3
CN1-25, 26 (SO1)
CN1-27, 28 (SO2)
CN1-29, 30 (SO3)
Input terminals
Select the /BK output terminal.
User Constant
Setting
Output Terminal (CN1)
*1
*2
Pn50F.2
0
--
--
1
25
26
2
27
28
3
29
30
Note
Signals are output with OR logic when multiple signals are allocated to the same
output circuit. Set other output signals to a value other than that allocated to the
/BK signal in order to output the /BK signal alone. See
5.3.4 Output Circuit Sig-
nal Allocation.