Using the Digital Operator
7.2.4 Manual Adjustment of the Speed and Torque Reference Offset
7 -30
Using the Panel Operator
1.
Press the MODE/SET Key to select the auxiliary function mode.
2.
Press the Up or Down Cursor Key to select the user constant Fn00B.
3.
Press the DATA/SHIFT Key for a minimum of one second, and the display will be as shown
below. The manual adjustment mode for the torque reference offset will be entered.
4.
Turn ON the Servo ON (/S-ON) signal. The display will be as shown below.
5.
Press the DATA/SHIFT Key for less than one second, to display the torque reference offset
amount.
6.
Press the Up or Down Cursor Key to adjust the offset amount. (Adjustment of torque refer-
ence offset)
7.
Press the DATA/SHIFT Key for less than one second, and the display will be as shown in
the above step 4.
8.
Press the DATA/SHIFT Key to return to the auxiliary function mode.
This completes the torque reference offset manual adjustment.