Wiring
3.3.3 Cable Specifications and Peripheral Devices
3 -14
3.3.2 Typical Main Circuit Wiring Example
The following figure shows a typical example of main circuit wiring (three-phase, 200 V).
M
FIL
1Ry
Main
power supply
ON
1RY
1KM
(For servo alarm display)
1SUP
1KM
L1
L2
L3
L1C
L2C
Servopack
SGDH-
jj
AE
U
V
W
A
B
C
D
PG
CN1
31
+24V
ALM
ALM-SG
32
1D
0
24
V
1Ry
1PL
Main
power supply
1KM
OFF
QF1
QF1: Molded-case circuit breaker (for the inverter)
FIL: Noise filter
1KM: Magnetic Contactor
1Ry: Relay
1PL: Indicator lamp
1SUP: Surge suppressor
1D: Flywheel diode
J
J
Designing a Power ON Sequence
Note the following points when designing the power ON sequence.
D
Design the power ON sequence so that power is turned OFF when a servo alarm signal is
output. (See the circuit figure above.)
D
Hold the power ON button for at least two seconds. The Servopack will output a servo alarm
signal for two seconds or less when power is turned ON. This is required in order to initialize
the Servopack.
2.0 s max.
Power supply
Servo alarm (ALM)
output signal
3.3.3 Cable Specifications and Peripheral Devices
Refer to the
SGM
j
H/SGDH User’s Manual: Servo Selection and Data Sheet
s (Manual No.:
SIE-S800-32.1).
3