3.2 Operating Procedures for Utility Functions
3.2.19 Reset Option Module Configuration Error (Fn014)
3-47
3
Utility Function
s
3.2.19
Reset Option Module Configuration Error
(Fn014)
If Option Modules are attached to the SERVOPACK, the SERVOPACK
detects the presence and models of the connected Option Models. If it
finds any errors, it outputs alarms. You can use this utility function to
reset those alarms.
Note: 1. This utility function is the only way to reset errors for Option Modules. The
errors are not reset when you reset alarms or turn OFF the power supply to the
SERVOPACK.
2. Always remove the cause of an alarm before you reset the alarm.
Preparations
Always check the following before you reset the Option Module detec-
tion alarm.
•
The parameters must not be write-prohibited (Fn010 must be set to
0000).