5.6 Operator Programming Error
YASKAWA ELECTRIC
TOEP C710687 02B FSDrive-MV1000 Instructions
173
T
ro
ubles
hoo
ting
5
Digital Operator Display
Error Name
oPE15
Torque Control Setting Error
Parameters settings not allowed in combination with Torque Control have been set.
Cause
Possible Solutions
When A1-02 = 3 (Closed loop vector control), the
following setting is specified:
• The torque control selection is specified at the same
time. d5-01=1 and H1-
= 71
• DROOP control and feed forward control are enabled
when torque control is selected: d5-01 = 1 or
H1-
= 71, and also b7-01
≠
0 or n5-01 = 1.
• KEB command 2 (N.O. input, N.C. input) is enabled
when torque control is selected: d5-01 = 1 or
H1-
= 71 and also H1-
= 7A or H1-
= 7b.
• The optimal deceleration and overexcitation
deceleration 2 are enabled when torque control is
selected (d5-01 = 1 or H1-
= 71) and (L3-04=2 or
L3-04 = 5).
Correct the settings of b7-01, d5-01, H1-
, L3-04 and n5-01.
Digital Operator Display
Error Name
oPE18
Online Tuning Parameter Setting Error
Parameters that control Online Tuning are not set correctly.
Cause
Possible Solutions
One of the following settings has occurred while Online
Tuning is enabled (n6-01 = 2) in Open Loop Vector
control (A1-02 = 2):
• E2-02 has been set below 30% of the original default
value.
• E2-06 has been set below 50% of the original default
value.
• E2-03 = 0
Set E2-02, E2-03, and E2-06 to the correct values.
Digital Operator Display
Error Name
oPE20
Commercial Power Supply/Drive Synchronous Transfer Function
The multi-function contact I/O used in the commercial synchronous switching
function has been selected incorrectly.
Cause
Possible Solutions
The necessary functions were not selected in the
commercial synchronous switching function in the
multi-function contact I/O.
• Set 82H and 83H in the multi-function contact input (H1-
).
• Set 40H and 41H in the multi-function contact input (H2-
).
Summary of Contents for FSDrive-MV1000 Series
Page 8: ...8 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 106: ...3 9 Wiring Check 106 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 210: ...6 7 Spare Parts 210 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 222: ...B 1 European Standards 222 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...