5-41
Continued
n011 : Frequency – Max. (Fmax)
n012 : Voltage – Max. (Vmax)
n013 : Frequency – Max. Voltage point (F
A
)
n014 : Frequency – Midpoint (F
B
)
n015 : Voltage – Midpoint (V
C
)
n016 : Frequency – Min. (Fmin)
n017 : Voltage – Min. (Vmin)
These seven parameters define the V/f pattern. The illustration below shows how these constants
relate to each other in establishing the custom V/f pattern.
NOTE: To establish a V/f pattern with a straight line from Fmin to F
A
, set
F
B
= Fmin. The setting of V
C
is then disregarded and does not affect the
V/f pattern.
IMPORTANT
The V/f parameter settings are checked each time the ENTER key is
pressed while programming the V/f parameters. A parameter set value
failure (Err ) will occur if any part of the following relationships among
n011 thru n017 is not TRUE:
(a)
Fmax
≥
F
A
≥
F
B
≥
Fmin
(b)
Vmax
≥
V
C
≥
Vmin
5.27 V/f PATTERN
V/f Characteristics Set by n011 thru n017
Vmax
(n012 )
OUTPUT
VOLTAGE
V
C
(n015 )
Vmin
(n017 )
Fmin
F
B
F
A
Fmax
(n016 )
(n014 )
(n013 )
(n011 )
OUTPUT FREQUENCY
Summary of Contents for GPD315/V7-4X
Page 1: ...GPD 315 V7 and V7 4X Technical Manual...
Page 4: ......
Page 20: ...xvi...
Page 22: ......
Page 40: ...1 18...
Page 52: ...3 2...
Page 56: ...4 4...
Page 101: ...5 45 PID Block Diagram...
Page 130: ...A1 8...
Page 134: ...A3 2...
Page 136: ...A4 2...
Page 146: ...A6 6...
Page 150: ...A7 4...
Page 154: ...A8 4...
Page 158: ......
Page 160: ......