9.19 Defaults by Bypass and Drive Model
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
693
No.
Name
Unit
Default
-
Bypass
Model
-
B052
B065
B077
B096
B124
B156
B180
B240
B302
o2-04
Drive
Model
(KVA)
Selection
Hex.
A0
A2
A3
A4
A5
A6
A7
A8
A9
E2-11
Motor
Rated
Power
HP
(kW)
30
(22)
40
(30)
50
(37)
60
(45)
75
(55)
100
(75)
125
(90)
150
(110)
200
(160)
L2-02
Power Loss
Ride
Through
Time
s
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
L2-03
Minimum
Baseblock
Time
s
1.0
1.1
1.1
1.2
1.2
1.3
1.5
1.7
1.8
L2-04
Powerloss V/
f Recovery
Ramp Time
s
0.6
0.6
0.6
0.6
1.0
1.0
1.0
1.0
1.0
L2-05
Undervoltage
Detection Lvl
(Uv1)
-
380
380
380
380
380
380
380
380
380
L3-24
Motor Accel
Time for
Inertia Cal
s
0.355
0.323
0.320
0.387
0.317
0.533
0.592
0.646
0.777
L8-02
Overheat
Alarm Level
°C
123
123
120
124
124
110
120
120
125
L8-09
Output
Ground Fault
Detection
-
1
1
1
1
1
1
1
1
1
L8-35
Installation
Method
Selection
-
2
2
2
2
2
2
0
0
0
L8-38
Carrier
Frequency
Reduction
-
2
2
2
2
2
2
2
2
2
n1-01
Hunting
Prevention
Selection
-
1
1
1
1
1
1
1
1
1
n1-03
Hunting
Prevention
Time
Constant
ms
10
10
10
10
30
30
30
30
30
Summary of Contents for H6B1A002
Page 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 74: ...Page Intentionally Blank...
Page 76: ...Page Intentionally Blank...
Page 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...