7.5 Program JOG Operation (Fn004)
7-11
7
Utili
ty Fu
ncti
ons (Fn
)
(5) Operating Procedure
Use the following procedure to perform the program JOG operation after setting a program JOG operation
pattern.
Pn533
Program JOG Movement Speed
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 10000
1 min
-1
500
Immediately
Setup
Pn534
Program JOG Acceleration/Deceleration Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
2 to 10000
1 ms
100
Immediately
Setup
Pn535
Program JOG Waiting Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 10000
1 ms
100
Immediately
Setup
Pn536
Number of Times of Program JOG Movement
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 1000
1 time
1
Immediately
Setup
(cont’d)
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Step
Display after
Operation
Keys
Operation
1
Press the MODE/SET Key to select the utility function.
2
Press the UP or DOWN Key to select Fn004.
3
Press the DATA/SHIFT Key for approximately one second. The
display shown on the left appears.
4
Press the MODE/SET Key to turn the servomotor power ON.
The display shown on the left appears.
5
Press the UP or DOWN Key according to the first movement
direction of the operation pattern. After the preset waiting time,
the movement starts.
Notes:
• Press the MODE/SET Key during operation, and the
servomotor power will turn OFF and the servomotor stops.
• Press the DATA/SHIFT Key for approximately one second
during operation, and the display of step 2 appears.
6
–
"End" flashes when the program JOG operation has been com-
pleted, and the screen returns to the display as shown on the left.
Notes:
• Press the MODE/SET Key, and the servomotor power will
turn OFF and the display of step 3 appears.
• Press the DATA/SHIFT Key for approximately one second,
and the display of step 2 appears.
7
When you finish program operation, turn the control power supply OFF and ON again.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/