3 Utility Function Mode
3.2.30 Anti-Resonance Control Adjustment Function (Fn204)
3-80
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The control must not be set to torque control.
• The write prohibited setting (Fn010) must not be set to write-protect parameters.
(2) Operating Procedure
With this function, an operation reference is sent, and the function is executed while
vibration is occurring.
The following methods can be used for the anti-resonance control adjustment func-
tion.
• Using Anti-Resonance Control for the First Time
• With Undetermined Vibration Frequency
• With Determined Vibration Frequency
• For Fine-tuning After Adjusting the Anti-Resonance Control
Using Anti-Resonance Control for the First Time
• With Undetermined Vibration Frequency
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main menu
for the utility function mode.
Use the
or
Key to move through
the list, select Fn204.
2
Press the
Key to display the initial set-
ting screen for tuning mode.
3
Press the
or
Key and set the tun-
ing mode “0.”
㧾㨁㧺ޓ ̆㧲㨁㧺㧯㨀㧵㧻㧺̆
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜
Status Display
㧾㨁㧺 ̆ 㨂㨕㨎 㧿㨡㨜̆
㨀㨡㨚㨕㨚㨓 㧹㨛㨐㨑 㧩 㧜