52
YASKAWA
TOEP C730600 74D LED Keypad Installation Manual
10.
Repeat steps 6 through 9 to input these parameter setting
values.
•
T1-02 [Motor Rated Power]
•
T1-03 [Motor Rated Voltage]
•
T1-04 [Motor Rated Current]
•
T1-05 [Motor Base Frequency]
•
T1-06 [Number of Motor Poles]
•
T1-07 [Motor Base Speed]
•
T1-08 [Encoder Pulse Count (PPR)]
: Input when setting
A1-02 = 3 [Control Method Selection = Closed Loop
Vector]
.
11.
Push
.
12.
Push
.
•
illuminates and Auto-Tuning starts.
• For Rotational Auto-Tuning, the drive injects current
into the motor for about 1 minute before rotating the
motor. For Inertia Tuning, the drive immediately begins
rotating the motor.
• Auto-Tuning will complete in 1 to 2 minutes.
■
Read Parameter Settings from the Drive (Backup)
Set
o3-02 = 1 [Backup Allowed = Enabled]
.
This operation example reads parameter settings from the drive and
saves them in the keypad. The keypad will save parameters from
one drive.