1 Preface and General Precautions

6

YASKAWA ELECTRIC

SIEP YEUOCL1 01A CANopen-Lift Communication Option Installation Manual

operation. All warnings from Yaskawa must be promptly issued to the end user. Yaskawa offers warranties only
for the quality of our products, in compliance with standards and specifications that are described in the manual.
Yaskawa does not offer other warranties, either explicit or implied. Yaskawa assumes no responsibility for
personal injury, property damage or loss, or compensation for damage caused by the incorrect application of our
products.

Note:

Be aware that serious injury or death may result if the warnings described in this manual are not observed. Yaskawa assumes no
responsibility for injuries or equipment damage to your company or customers that are caused by a failure to observe the information
contained in this manual.

Read this manual carefully when mounting, operating, and repairing AC drives and Communication options.

Follow all warnings, cautions, and instructions.

All work should be carried out by qualified personnel.

Ensure the drive is installed to an area that matches the following conditions.

DANGER

Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before

servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal
capacitor stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage
decreases below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make
sure that the drive is safe. Failure to obey will cause death or serious injury.

WARNING

Fire Hazard. Do not connect power supply wiring to drive output terminals U/T1, V/T2, and W/T3. Connect

power supply wiring to main circuit input terminals R/L1, S/L2, and T/L3. Failure to obey can cause death or serious injury.

WARNING

Electrical Shock Hazard. Do not make changes to the drive body or drive circuitry. Failure to obey can cause

death or serious injury and will void warranty. Yaskawa is not responsible for changes to the product made by the user.

WARNING

Electrical Shock Hazard. Only let authorized persons install, wire, maintain, examine, replace parts, and

repair the drive. Failure to obey can cause death or serious injury.

WARNING

Electrical Shock Hazard. Always ground the motor-side grounding terminal. Contacting the motor case can

cause death or serious injury from incorrect equipment grounding.

WARNING

Electrical Shock Hazard. Do not work on the drive or around the drive while wearing loose clothing or jewelry.

Tighten loose clothing and remove all metal objects such as watches or rings. Failure to obey can cause death or serious injury.

WARNING

Electrical Shock Hazard. The leakage current of the drive will be more than 3.5 mA in drive models 2xxxB,

2xxxC, 4002B to 4371B, 4002C to 4371C (with built-in EMC filter turned ON) and 4389 to 4675. The IEC/EN 61800-5-1: 2007
standard specifies that users must wire the power supply to automatically turn off when the protective ground wire disconnects.
Users can also connect a protective ground wire that has a minimum cross-sectional area of 10 mm

2

(copper wire) or 16 mm

2

(aluminum wire). Failure to obey these standards can cause death or serious injury.

WARNING

Sudden Movement Hazard. Remove all persons and objects from the area around the drive, motor, and load

before starting Auto-Tuning. The drive and motor can start suddenly during Auto-Tuning and cause death or serious injury.

WARNING

Sudden Movement Hazard. Remove all persons and objects from the area around the drive, motor, and

machine area and attach covers, couplings, shaft keys, and machine loads before energizing the drive. Failure to obey can
cause death or serious injury.

WARNING

Fire Hazard. Do not use the main circuit power supply (Overcurrent Category III) at incorrect voltages. Make

sure that the drive rated voltage aligns with the power supply voltage before energizing the drive. Failure to obey can cause
death or serious injury.

WARNING

Fire Hazard. Do not put flammable or combustible materials on top of the drive and do not install the drive

near flammable or combustible materials. Attach the drive to metal or other noncombustible material. Failure to obey can cause
death or serious injury.

WARNING

Fire Hazard. Tighten all terminal screws to the correct tightening torque. Connections that are too loose or too

tight can cause incorrect operation and damage to the drive. Incorrect connections can also cause death or serious injury from
fire.

WARNING

Electrical Shock Hazard. Do not cause a short circuit on the drive output circuit. Failure to obey can cause

death or serious injury.

WARNING

Electrical Shock Hazard. Always use a type B Residual Current Monitor/Residual Current Device (RCM/RCD)

where a residual current operated protective or monitoring device protects against direct or indirect contact as specified by IEC/
EN 60755 The drive can cause a residual current with a DC component in the protective earthing conductor. Failure to obey can
cause death or serious injury.

WARNING

Electrical Shock Hazard. Ground the neutral point on the power supply of drive models 2xxxB/C and 4xxxA/B/

C to comply with the EMC Directive before turning on the EMC filter or if there is high resistance grounding. If the EMC filter is
switched ON without the neutral point being grounded or if there is high resistance grounding, it can cause death or serious
injury.

Summary of Contents for L1000A Series

Page 1: ...MANUAL NO SIEP YEUOCL1 01A CANopen Lift Communication Option Communication Option Card for Lift Inverter Drive YASKAWA L1000A Installation Manual Type SI L3...

Page 2: ...This Page Intentionally Blank 2 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual...

Page 3: ...cable Models 8 3 Receiving 8 Receiving the Option Card 8 Content and Packaging 8 Tools Required 8 4 CANopen Lift Option Components 9 CANopen Lift Option SI L3 9 CANopen Lift Option Status LEDs 9 RUN L...

Page 4: ...4 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual 8 Specifications 17 Revision History 18...

Page 5: ...B Printed Circuit Board FCS Frame Check Sequence INVR MEMOBUS register number EDS Electronic Data Sheet file About Registered Trademarks CANopen is a registered Community Trademark of CAN in Automatio...

Page 6: ...lothing and remove all metal objects such as watches or rings Failure to obey can cause death or serious injury WARNING Electrical Shock Hazard The leakage current of the drive will be more than 3 5 m...

Page 7: ...Make sure that all connections are correct after you install the drive and connecting peripheral devices Failure to obey can cause damage to the drive Intended Use This communication option card is e...

Page 8: ...ns Make sure to read and understand the safety information and precautions before using the product Receiving the Option Card Please perform the following tasks after receiving the Communication Optio...

Page 9: ...ANopen Lift Option has two LEDs that indicate the communication status RUN LED LED Color Display Meaning RUN Green On The device is in Operational State Green Blinking The device is in Pre Operational...

Page 10: ...e Communication Option card is connected to the network using a 9 pin D sub connector flickering on 50 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200...

Page 11: ...option card to the network using a 9 pin D sub connector wired like shown below Figure 4 3 Wiring Diagram Note The FE terminal on the Communication Option must be connected to the drive ground termin...

Page 12: ...will void warranty Yaskawa is not responsible for changes to the product made by the user WARNING Fire Hazard Tighten all terminal screws to the correct tightening torque Connections that are too loos...

Page 13: ...or I LED labels J Front cover Figure 5 1 Installing the Option Card 5 Prepare the 9 pin D sub network cable connectors For inverter drives CIMR Lx4F0002 to 0023 the network cable should be routed to t...

Page 14: ...equency Reference Selection Selects the frequency reference input source 0 Operator Digital preset speed d1 01 to d1 17 1 Terminals Analog input terminals 2 MEMOBUS Modbus communications 3 Option card...

Page 15: ...on Channel 1 Memobus Modbus 3 DCP 3 4 DCP 4 5 CANopen Lift 1 o1 03 Digital Operator Display Selection Sets the units to display the frequency reference and output frequency 0 0 01 Hz 1 0 01 100 E1 04...

Page 16: ...option card connected to connector CN5 A is not compatible Connect the option card to the correct connector Note Encoder option cards are not compatible with connector CN5 A oFA01 Option Fault Connect...

Page 17: ...mmunications is incorrect On the last drive in a MEMOBUS Modbus network set DIP switch S2 to the ON position to enable the termination resistor EEP EEPROM Checksum Error Communication wiring is faulty...

Page 18: ...18 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual Revision History Date of Publication Revision Number Section Revised Content November 2017 First Edition...

Page 19: ...YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual 19...

Page 20: ...that may apply Specifications are subject to change without notice for ongoing product modifications and improvements 2017 YASKAWA Europe GmbH YASKAWA Europe GmbH MANUAL NO SIEP YEUOCL1 01A 1 0 Publi...

Reviews: