5 Installation Procedure
22
YASKAWA ELECTRIC
TOBP C730600 63C V1000 Option SI-ET3/V Installation Manual
7.
For models CIMR-V
BA0001F to BA0003F, 2A0001F to 2A0006F, loosen the
screws attaching the NEMA Type 1 conduit bracket to the drive to remove the
NEMA Type 1 conduit bracket.
Figure 11
Figure 11 Remove the NEMA Type 1 Conduit Bracket
8.
On NEMA Type 1 enclosure models (CIMR-V
BA0001F to BA0003F, 2A0001F to
2A0006F), the screw for the drive ground terminal also acts as one of the screws
that attaches the NEMA Type 1 conduit bracket to the drive. Reattach the NEMA
Type 1 conduit bracket according to
and connect the drive-side of the
ground wire to the drive ground terminal.
Note:
The four different ground wires packaged with the option connect the option to different drive
models. Select the proper ground wire depending on drive size. Refer to
on page
for
ground wire selection by drive model.
Figure 12
Figure 12 Reattach the NEMA Type 1 Conduit Bracket and Connect the Ground Wire for models
CIMR-V
BA0001F to BA0003F, 2A0001F to 2A0006F
V1000
Ground terminal
Ground wire
Drive ground terminal/
NEMA Type 1 conduit
bracket screw
Ground wire
Drive-side
connector
Screw size:
M3.5 to M6
Option unit
connector
Screw size: M3
V1000
GEM_M-III_IM_E_conditional.fm 22 ページ 2017年7月7日 金曜日 午後5時9分