Appendix B List of Parameters
B-14
Sequence-
related
Switches
Pn50A
0
Input Signal
Allocation Mode
1
Manual signal allocation
(Automatically sets to 1 when the NS115 is
connected.)
1
1
/S-ON Signal
Mapping
8
Set to 8. (Automatically sets to 8 when the
NS115 is connected.)
8
2
/P-CON Signal
Mapping
8
Set to 8. (Automatically sets to 8 when the
NS115 is connected.)
8
3
P-OT Signal
Mapping
0
Inputs from the SI0 (CN1-40) input terminal.
2
∆
1
Inputs from the SI1 (CN1-41) input terminal.
2
Inputs from the SI2 (CN1-42) input terminal.
3
Inputs from the SI3 (CN1-43) input terminal.
4
Inputs from the SI4 (CN1-44) input terminal.
5
Inputs from the SI5 (CN1-45) input terminal.
6
Inputs from the SI6 (CN1-46) input terminal.
7
Sets signal ON.
8
Sets signal OFF.
9
Inputs the reverse signal from the SI0 (CN1-
40) input terminal.
A
Inputs the reverse signal from the SI1 (CN1-
41) input terminal.
B
Inputs the reverse signal from the SI2 (CN1-
42) input terminal.
C
Inputs the reverse signal from the SI3 (CN1-
43) input terminal.
D
Inputs the reverse signal from the SI4 (CN1-
44) input terminal.
E
Inputs the reverse signal from the SI5 (CN1-
45) input terminal.
F
Inputs the reverse signal from the SI6 (CN1-
46) input terminal.
Table B.3 Function Switches List (cont’d)
Category
Pn No.
Digit
Place
Name
Setting
Description
SGDH
Factory
Setting
Changing
Method *