Ala
rm L
ist
Ala
rm
Numb
er
(
4
00
0 to
49
99)
Alarm List-450
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2
Group axis being used:
The job operated by another
sub task uses the same group
axis.
Setting error
(1)Reset the alarm.
(2)Check if the control group of the JOB which is used in the PSTART
has been already executed in other task. If the same group need to be
executed in series, add PWAIT to confirm if the other task end.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3
Multiple start of same job:
The job that was tried to be
started was executed by
another sub task.
Setting error
(1)Reset the alarm.
(2)Check if the JOB which is used in the PSTART has been already
executed in other task. If the same job need to be executed in series,
add PWAIT to confirm if the other task end.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4
Unregistered master job:
Although the master job was
not registered, an attempt was
made to execute PSTART
SUB (job name omitted).
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
The master job of the subtask is registered
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5
Synchronization instruction
error:
When restarted by PSTART,
synchronization instruction
status of the sub task under
interruption was different from
the status to restart.
Setting error
(1)Reset the alarm.
(2)Check the following settings.
∙
The job to be started
∙
The execution timing for start command
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause