Alar
m List
Alar
m Nu
mbe
r (4
00
0 to
4
9
99
)
Alarm List-577
55
Pair coordinate system
position calculation function
error
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
56
OPT higher acceleration and
deceleration control is not
allowed when Function
acceleration and deceleration
control is enabled.
Setting error
(1)Check the following settings.
∙
OPT higher acceleration and deceleration control is used.
∙
Don't use the OPT higher acceleration and deceleration control.
other
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
57
Arithmetic error occurred
when calculating the
acceleration and deceleration
time (Function acceleration
and deceleration control)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
58
Arithmetic error occurred
when recalculating the
acceleration and deceleration
time (Function acceleration
and deceleration control)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
59
Arithmetic error occurred
when calculating PL control
(Function acceleration and
deceleration control)
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
60
Arithmetic error occurred
when calculating Function
acceleration and deceleration
dry run.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
61
Arithmetic error occurred
when calculating current path
of continuous motion stop
operation
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy