Disassembly
1. Turn OFF the DX100 power supply, then drain grease.
2. Connect the backup battery. (Refer to
.)
3. Remove the cross head APS bolts , then remove the cover .
4. Disconnect the connector (signal, power) of the internal wiring
harness.
5. Support the U-arm with a chain block, etc. so that the U-arm does not
rotate before removing the U-axis motor .
6. Remove the GT-SA bolts . Insert stud bolts M6 (length of the thread
part: 30 mm or more) in the tapped holes M6 (2 holes) on the flange
face of the U-axis motor . Screw the stud bolts in until the gap
between the motor and the matching surface becomes 10 mm or
more. Then, remove the U-axis motor horizontally from the casing.
7. Remove the hexagon socket head cap screw , then remove the input
gear and the key .
Reassembly
1. Mount the key and the input gear on the U-axis motor .
(The key is attached to the U-axis motor .)
2. Put the conical spring washer on the hexagon socket head cap
screw , then apply Loctite 242 to the thread part of the screw. Then,
tighten it with the tightening torque shown in
.
3. Apply ThreeBond 1206C on the matching surface between the flange
face of the U-axis motor and the casing. Then, mount the U-axis
motor on the casing.
4. Tighten the GT-SA bolts with the tightening torque shown in
3 "U-Axis Motor Parts Checklist"
.
5. Connect the connector (signal, power) of the internal wiring harness to
the U-axis motor .
6. Mount the cover with the cross head APS bolts .
7. Replenish grease (VIGO Grease RE No.0) through the grease inlet.
8. Remove the backup battery.
9. Remove the chain block, etc. which support the U-arm.
10. Turn ON the DX100 power supply.