10 MLX200 Control Module Software Version Upgrade Procedure
10.7 Import the Robot Data into RSLogix
10-6
168283-1CD
168283-1CD
Hardware Installation &
Software Upgrade
10.7
Import the Robot Data into RSLogix
Using MLx200 Job software, re-load the Job Teach Points, Interference
Zones, Tools and User Frames by referencing
.
1. Place the PLC in program mode.
2. In the Import Data area of the MLx200 Job main screen, press [...] to
browse to a directory location where the data was stored.
3. Highlight each file to be imported, by pressing [Cntrl]-[Left Mouse
Button], and press [Open].Observe all data in
Robot Data for RSLogix Ladder”
is imported into the new RSLogix
ladder.
4. Press [Start Import of Listed Files].
5. After files are imported, a confirmation message will be displayed.
Press [OK] to continue.
10.8
Configure the new MLX200-HMI file to see the
“MLX200x_x_x” processor.
chapter 13 "HMI Communications Setup Procedure"
and
complete the steps on how to setup the Factory Talk View HMI when a
MER is used. (This should only be required for MLX200 software
versions 1.2 or earlier.)
NOTE
The “x_x_x” represents the software version number in the
file name. An example of the actual file name may be
MLX200_HMI_1_2_0.mer. MER files are no longer provided
as of version 1.3 release. Now all MLX200 systems include
a more flexible APA file which allow easier customization
and deployment.
85 of 121