5-10
173124-1CD
HW1482991
5
Basic Specifications
5.6 Alterable Operating Range
MPL300
II
5.6.3 Adjustment of the Soft Limit of the S-Axis Pulse
Apply the Instruction for “DX200 Instructions chapter 8.17 Changing the
Parameter Setting” as part of reference materials for adjusting the
programming pendant when modifying the range of motion of S-Axis.
Pulse limit (positive (+) direction of the S-axis): S1CxG400
Pulse limit (negative (-) direction of the S-axis): S1CxG408
MPL300
II
Degree
Number of Pulse
0
°
0
±
15
°
1)
1 Refer to
section 5.6 “Alterable Operating Range”
.
±
34092
±
30
°
±
68183
±
45
°
±
102275
±
60
°
±
136367
±
75
°
±
170458
±
90
°
±
204550
±
105
°
±
238642
±
120
°
±
272733
±
135
°
±
306825
±
150
°
±
340917
±
165
°
±
375008
±
180
°
±
409100
NOTE
Adjust both of the pulse limit and the angle of the S-axis
mechanical stopper when modifying the range of motion of
the manipulator.
37 of 100