9-6
173124-1CD
HW1482991
9
Maintenance and Inspection
9.2 Notes on Maintenance Procedures
MPL300
II
1. Turn OFF the DX200 main power supply.
2. Remove the plate fixing screws and the plate on the connector base,
then pull the battery pack out to replace it with the new one.
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack to the unoccupied connector on the
board.
5. Remove the old battery pack from the board.
6. Mount the new battery pack to the holder.
7. Reinstall the plate.
NOTE
Remove the old battery pack after connecting the new one
so that the encoder absolute data does not disappear.
NOTE
Do not allow the plate to pinch the cables when reinstalling
the plate.
69 of 100