5
Basic Specifications
5.6 Alterable Operating Range
5-7
173124-1CD
HW1482991
MPL300
II
5.6
Alterable Operating Range
The operating range of the S-axis can be altered in accordance with the
operating conditions as shown in
Table 5-2 “S-Axis Operating Range”
If alteration is necessary, contact your YASKAWA representative in
advance.
* The interval between stoppers must be 60° or more.
Table 5-2: S-Axis Operating Range
Item
Specifications
S-Axis Operating
Range
±180°(standard)
*(±165°)
±150°
±135°
±120°
±105°
± 90°
± 75°
± 60°
± 45°
± 30°
*(± 15°)
NOTE
When altering the operating range to ±15° or ±165°, please
contact your YASKAWA representative.