4
Wiring
4.1 Grounding
MS165
4
Wiring
4.1
Grounding
Follow electrical installation standards and wiring regulations for
grounding. A ground wire of 5.5 mm
2
or more is recommended.
Refer to
to connect the ground line directly
to the manipulator.
WARNING
•
Ground resistance must be 100
or less.
Failure to observe this warning may result in fire or electric shock.
•
Before wiring, make sure to turn the primary power supply off, and
put up a warning sign. (ex. DO NOT TURN THE POWER ON.)
Failure to observe this warning may result in fire or electric shock.
CAUTION
•
Wiring must be performed by authorized or certified personnel.
Failure to observe this caution may result in fire or electric shock.
•
Do not cover the cable or allow it to tangle. Keep the cable as
straight as possible.
Failure to observe this caution may result in preventing heat of the
cable from being discharged.
NOTE
• Never use this line sharing with other ground lines or
grounding electrodes for other electric power, motor
power, welding devices, etc.
• Where metal ducts, metallic conduits, or distributing racks
are used for cable laying, ground in accordance with elec-
trical installation standards.
26 of 100