8
Electrical Equipment Specification
8.2 Internal Connections
8-4
167109-1CD
HW1482308
MS165
8.2
Internal Connections
Highly reliable connectors are equipped on each connection part of the
manipulator to enable easy removal and installation for maintenance and
inspection. For the number and location of connectors, see
“Locations and Numbers of Connectors”
.
Diagrams for Internal connections of the manipulator are shown in
fig. 8-5(a) “Internal Connection Diagram”
Fig. 8-4: Locations and Numbers of Connectors
Connector for
internal user I/O
wiring harness
(Base)
Connector for external axis
(Power cable)
Connector for external axis
(Encoder cable)
Connector for internal user
I/O wiring harness
2BC
1BC
Table 8-1: List of Connector Types
Name
Type of Connector
Connector Base
Connector for internal
user I/O wiring harness
JL05-2A24-28PC
(JL05-6A24-28S: Optional)
U-arm
Connector for internal
user I/O wiring harness
JL05-2A24-28SC
(JL05-6A24-28P: Optional)
Connector for external axis
(Encoder cable)
JL05-2A20-29SC
(JL05-6A20-29P: Optional)
Connector for external axis
(Power cable)
JL05-2A18-1SC
(JL05-6A18-1P: Optional)