47
9.1.2
Inspection While the Power is ON (Robot is in operating)
9.2
Maintenance procedures
9.2.1
Battery pack replacement
Table 10: Inspection Position
Inspection Position
Inspection Place
Dail
y
month
ly
Quarterly
half-
yearly
annuall
y
Check motion range
Each joint
Move the cables back and forth
lightly to check whether the cables
are disconnected.
External cables
(including cable unit of
the robot)
Push each arm in MOTOR ON
status to check whether backlash
exists.
Each arm
Check whether unusual sound or
vibration occurs.
Whole
Measure the accuracy repeatedly
by a gauge.
Whole
WARNING
Do not insert or pull out the motor connectors while the power to the
robot system is turned ON. Inserting or pulling out the motor
connectors with the power ON is extremely hazardous and may result
in serious bodily injury as the robot may move abnormally. It can also
may result in electric shock and/or malfunction of the robot system.
To shut off power to the robot system, pull out the power plug from the
power source. Be sure to connect the AC power cable to a power
receptacle. DO NOT connect it directly to a factory power source
Before performing any replacement procedure, turn OFF the
Controller and related equipment, and then pull out the power plug
from the power source.
Performing any replacement procedure with the power ON is
extremely hazardous and may result in electric shock and/or
malfunction of the robot system.
Summary of Contents for MOTOMAN MYS450L
Page 26: ...26 E1101000117GB01 MYS450L 5 3 Dimensions 4 5 12 1 200 6 7 8 9 10 3 11 Dimensions mm...
Page 40: ...40 E1101000117GB01 MYS450L 8 Electrical Equipment Specification 8 1 Signal cable BASE ARM2...
Page 41: ...MYS450L E1101000117GB01 41 8 2 Power cable BASE ARM2...
Page 60: ...60 E1101000117GB01 MYS450L...
Page 61: ...MYS450L E1101000117GB01 61...