1.1 Coordinated Control
1-1
1
Independent/Coordinated Control
Function
With the NX100, a system can be configured to control multiple manipulators or stations
simultaneously with a single controller.
With the independent / coordinated control function, manipulators and/or stations can be oper-
ated together or individually. Operation can be optimized for the jobs.
1.1
Coordinated Control
With this function, manipulators or stations execute jobs in a coordinated motion.
<Example>
Using two coordinated manipulators to execute a job.
NOP
SMOVL
+MOVL
Job
14/210